 GWY-500 Operations
GWY-500 is a Protocol Converter / Data sharer for devices like PLCs, Inverters, Controllers etc. GWY-500 has a serial port, that connects to a serial device and a Profibus-DP-V0 port, that connects to Profibus network. Gateway allows serial devices to act as a slave on a Profibus network. It also allows Profibus Master PLCs to act as a serial device (e.g. Modbus Master or Modbus Salve).

Our Windows® based Gateway setup software makes it easy to configure the protocol converter. After choosing which protocol to be used for each port, you can program the Gateway to transfer the data blocks. Using a simple spreadsheet format, you can simply program the Gateway to fetch a specified number of registers or bits from one device and transfer them to the other. Powerful software allows you to have all the information transfers done continuously or allows the PLC to control which blocks of data are to be transferred. 

System requirements for Gateway Setup Software are:
Programming software is common for the entire Gateway family.
   
Windows Version   : Microsoft Windows 9x/NT/2000/XP
Processor             : PENTIUM or higher
Hard disk Space    : 5 MB or more
Mouse                  : Required
RAM                     : 16 MB or more
Display resolution  : 800 X 600 (VGA) or better
Display colors       : 16 bit color 

Other Accessories required for the GWY-500 configuration and to use in actual application:
1. Gateway Configuration / Connecting Cable.
2. Gateway Setup Software .
3. Devices with communication cables.

Communication ports:
The GWY-500 has two communication ports. Pin-out of these ports are as shown below:

   
        
   


                    
                                               
*Do not use pin no. 6 of PLC1/COM1 port.

Data Line: The Profibus user group recommends the following colour coding for the data signal lines: A-Data Line = Green B-Data Line = Red
These data signal lines must be connected to the corresponding signal terminals or pins at the master unit and other stations (i.e. A to A, B to B).

RTS: The signal RTS (TTL signal relative to Data Ground) is meant for the direction control of repeaters in case repeaters without self control capability are used.

+5V DC, Data Ground: The signals +5V DC and Data Ground are meant to power an externally mounted bus terminator. 

The powering of the 220 W termination resistor ensures a defined idle state potential on the data lines. To ensure proper functioning up to the highest baud rate, each bus segment has to be terminated at both ends of the cable.